HOME DEEPWATER PRODUCT INDEX CONTACT US PDF BROCHURE
MA-1 Monitored Anode (the "CP Fuel Gauge")

Product Overview

The Polatrak MA-1 provides a reliable, accurate method for monitoring anode performance and consumption. It can be hardwired to the surface, or connected to a SunStation subsea readout, making it suitable for any depth.

The MA-1 allows accurate logging of the total number of Ampere-hours delivered by the anode. The time-consuming acts of cleaning an anode and then visually estimating consumption (an inherently unreliable exercise) are no longer required. The unique design of the monolithic isolators used in the system provides 100% life cycle reliability; there are no insulated flange joints to fail. The double armored wires used on all Polatrak instruments ensure full life cycle performance.

Polatrak monitors have an excellent track record of success and are installed on more offshore structures worldwide than any other fixed monitoring system. The system has been applied to all galvanic anode types, platform anodes, flush mount anodes and pipeline bracelet anodes.

Applications

1. Offshore platform jackets & drill rigs
2. Sea-water ballast banks on SPAR, TLP, and FSU / FPSO structures
3. SPAR center well areas
4. Inshore structures, piers, jetties, wharves
5. Subsea equipment (when used with SunStation subsea readout)
6. Offshore pipelines

Main Benefits

1. Allows accurate measurement of anode consumption and remaining life without interference with the anode.

2. Gives direct verification of CP design criteria.

3. Proven reliability; these instruments are installed on many of the worlds premier offshore structures and have been used to write the book on CP design in many emerging offshore areas.

4. Guaranteed performance; Polatrak instruments come with the best warranty in the industry.

Specifications

Cable - 4 x 12 AWG, two conductor, double armored, polyurethane insulated and jacketed cable.

Shunt - Precision 0.0025 ohm (50 mV=20 A). Single or Double leg monitoring.

Isolator - Delrin monolithic joint.

Options - 1. Single or dual shunted legs (If one leg, then the other end shall be insulated as above, without the shunt). 2. Full anode assembly or monitored legs only.


Back to the Polatrak Diagram

TO ORDER and for more info, visit stoprust.com
Monitoring anode consumption allows an operator to predict CP system life.
MA-1 wrapped with cable and custom mounts, ready to go on the pallet.
MA-1 bracelet anode, installed in Alaska.
deepwater corrosion services inc. - 10851 train court, houston, tx 77041 - (713) 983 7117 - www.stoprust.com